<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-17 18-33-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 77 dBuV NOSTALGI
Pilot RDS Phase Difference
6.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
7 kHz 68 kHz 19040 0,0420
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 5,34 dBr 6,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Harpo - Movie star "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 68 kHz MIN: 7 kHz % above 76 kHz: 0,0420 Acquired: 2025/02/17 18.32.25 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 6,9 dBr MIN: 2,3 dBr AVE: 5,34 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/02/17 18.32.25) 18.18 18.20 18.22 18.24 18.26 18.28 18.30 18.32 0 2 4 6 Pm [dBr]